Standard Detail Drawings
Complet Sets and Individual Drawings Available in Adobe Acrobat, AutoCAD and MicroStation Formats
Welcome to your one stop shop for accessing all City of Raleigh Standard Detail Drawings.
The standard detail drawings below apply to all infrastructure construction plans. They are intended to be used as a guide in the preparation and submittal of plans for private development and city contract projects within the City of Raleigh and the city's extra-territorial jurisdiction.
All construction shall conform to either these City of Raleigh specifications or to the latest edition of the NCDOT Standard Specifications for Road and Structures. If a required detail is not included on this web page, the North Carolina Department of Transportation (NCDOT) Roadway Standard Drawings shall apply. Any questions regarding the NCDOT Standard Drawings should be directed to the NCDOT, Design Services Unit at 919-250-4128.
Drainage
Complete Drainage Standard Detail Drawings:
Individual Drainage Standard Detail Drawings:
| Detail | Description | Format | ||
| 30.01 | 5' O.M. Catch Basin | |
dwg | dgn |
| 30.02 | Double Width Catch Basin | |
dwg | dgn |
| 30.03 | Standard Drop Inlet | |
dwg | dgn |
| 30.04 | Standard Junction Box | |
dwg | dgn |
| 30.05 | Standard Class "A" Manhole | |
dwg | dgn |
| 30.11.1 | Catch Basin Castings | |
dwg | dgn |
| 30.11.2 | Bolted Cover Assembly | |
dwg | dgn |
| 30.12 | Catch Basin Steel Top | |
dwg | dgn |
| 30.13 | Drop Inlet Casting | |
dwg | dgn |
| 30.14 | Standard Drop Inlet Castings | |
dwg | dgn |
| 30.15 | Standard Storm Manhole Cover | |
dwg | dgn |
| 30.21 | Pipe Under Drain Detail | |
dwg | dgn |
Contacts:
Paul Kallam
Public Works Department
Fire
Fire Apparatus
Individual Fire Apparatus Standard Detail Drawings:
| Detail | Description | Format | ||
| FP-29 | Apparatus Access Alternate Compliance | |
dwg | dgn |
Fire Sprinklers and Water
Individual Fire Sprinklers and Water Standard Detail Drawings:
| Detail | Description | Format | ||
| FP-15 | Yard FDC Storz | |
dwg | dgn |
| FP-16 | Hotbox FDC Storz Requirements | |
dwg | dgn |
| FP-17A | Hotbox Inline Backflow | |
dwg | dgn |
| FP-17B | Hotbox Inline Backflow | |
dwg | dgn |
| FP-18A | Retrofit Backflow Inline (vault) | |
dwg | dgn |
| FP-18B | Retrofit Backflow Inline (vault) | |
dwg | dgn |
| FP-19 | Retrofit Backflow Preventer | |
dwg | dgn |
| FP-27 | Hotbox with freestanding FDC | |
dwg | dgn |
Fire Alarm & Sprinklers
Individual Fire Alarm & Sprinkler Standard Detail Drawings:
| Detail | Description | Format | ||
| FP-1 | Sprinkler Design Data | |
dwg | dgn |
| FP-2 | Sprinkler Reflected Ceiling | |
dwg | dgn |
| FP-3 | Sprinkler Piping Plan | |
dwg | dgn |
| FP-4 | Sprinkler Riser Detail (Dry) | |
dwg | dgn |
| FP-4 | Sprinkler Riser Detail (Wet) | |
dwg | dgn |
| FP-5 | Riser Clearance Detail | |
dwg | dgn |
| FP-6 | Standpipe Pressure Summary | |
dwg | dgn |
| FP-7 | Fire Pump Isometric | |
dwg | dgn |
| FP-8 | Fire Pump Elevations | |
dwg | dgn |
| FP-9 | Sprinkler Legend Typical | |
dwg | dgn |
| FP-10 | Equipment Schedule | |
dwg | dgn |
| FP-11 | Fire Stop Detail | |
dwg | dgn |
| FP-12 | Fire Department Hose Valve Cabinet | |
dwg | dgn |
| FP-12 | Fire Department Hose Valve | |
dwg | dgn |
| FP-13 | Typical Pipe Hanger | |
dwg | dgn |
| FP-14 | Flush FDC Storz | |
dwg | dgn |
| FP-20 | Record Document Storage | |
dwg | dgn |
| FP-21 | Underground Fire Line through Footing | |
dwg | dgn |
| FP-22 | Riser Detail (multiple riser) | |
dwg | dgn |
| FP-23 | Insulation Detail | |
dwg | dgn |
| FP-24 | Shunt Trip Supervisory Detail (alarm) | |
dwg | dgn |
| FP-25 | Elevator Pit Dry System Detail | |
dwg | dgn |
| FP-26 | Fire Alarm Device Mounting | |
dwg | dgn |
| FP-28 | Sprinkler Details | |
dwg | dgn |
| FP-30 | Floor Control Details | |
dwg | dgn |
| FP-31 | Fire Alarm Matrix (FP-31a - FP-31e) | |
dwg | dgn |
Contact:
Fire Construction Supervisor
Reuse
Complete Reuse Standard Detail Drawings:
Individual Reuse Standard Detail Drawings:
| Detail | Description | Format | ||
| R-1 | Temporary Reuse Main Blow Off Assembly | |
dwg | dgn |
| R-2 | Permanent Reuse Main Blow Off Assembly | |
dwg | dgn |
Contacts:
Cesar Sanchez
Public Utilities Department
Sewer
Complete Sewer Standard Detail Drawings:
Individual Sewer Standard Detail Drawings:
| Detail | Description | Format | ||
| S-1 | Standard Bedding for RCP | |
dwg | dgn |
| S-2 | Standard Concrete Pavement Patch | |
dwg | dgn |
| S-3 | Standard Asphalt Pavement Patch | |
dwg | dgn |
| S-4 | Trench Bottom Dimensions & Backfilling Requirements for DIP and RCP | |
dwg | dgn |
| S-5 | Trench Bottom Dimensions and Backfilling Requirements for PVC Gravity Sewer Main | |
dwg | dgn |
| S-6 | Thrust Blocking Design Data for Sewer Force Main | |
dwg | dgn |
| S-7 | Standard Thrust Blocking Views | |
dwg | dgn |
| S-8 | Standard Main Marker for Sewer Force Mains In Easements | |
dwg | dgn |
| S-9 | Standard Sewer Force Main Air Release Valve | |
dwg | dgn |
| S-10 | Aerial Pipe Crossing General Notes | |
dwg | dgn |
| S-11 | Aerial Pipe Crossing Typical Plans | |
dwg | dgn |
| S-12 | Aerial Pipe Crossing Steel Casing Pipe Elevation | |
dwg | dgn |
| S-13 | Aerial Pipe Crossing Typical Pipe Section & Elevation | |
dwg | dgn |
| S-14 | Aerial Pipe Crossing Concrete Pier | |
dwg | dgn |
| S-15 | Aerial Pipe Crossing Pile Cap | |
dwg | dgn |
| S-16 | Aerial Pipe Crossing Pile Supported Pier | |
dwg | dgn |
| S-17 | Aerial Pipe Crossing Concrete Pier on Bedrock | |
dwg | dgn |
| S-18 | Aerial Pipe Crossing Casing Pipe | |
dwg | dgn |
| S-19 | Aerial Pipe Crossing Concrete Support | |
dwg | dgn |
| S-20 | Standard Pre-cast Sanitary Sewer Manhole | |
dwg | dgn |
| S-21 | Extended Bases or Cast-in-Place Reinforced Concrete Base | |
dwg | dgn |
| S-22 | Standard Manhole Installation over Existing Sewer Main | |
dwg | dgn |
| S-23 | Standard High Velocity Manhole Invert | |
dwg | dgn |
| S-24 | Standard Seal Tight Manhole w/ Vented Stack | |
dwg | dgn |
| S-25 | Standard Manhole Cover | |
dwg | dgn |
| S-26 | Manhole Frame and Watertight Cover | |
dwg | dgn |
| S-27 | Watertight Manhole Frame with Cam Lock Cover | |
dwg | dgn |
| S-28 | Standard Slip Resistant Manhole Step Detail | |
dwg | dgn |
| S-29 | Standard Slip Resistant Manhole Step Detail within Paved Surfaces | |
dwg | dgn |
| S-30 | Typical Sanitary Sewer Lateral Connection | |
dwg | dgn |
| S-31 | Lateral Saddle Installation Detail for PVC Pipe | |
dwg | dgn |
| S-32 | Lateral Saddle Installation Detail for VCP and DIP | |
dwg | dgn |
| S-33 | Main Extension to Tie into Tee Manhole | |
dwg | dgn |
| S-34 | 4” Cleanout Plug | |
dwg | dgn |
| S-35 | Minimum Requirements for Pump Station (Layout) | |
dwg | dgn |
| S-36 | Pump Station Electrical Panel | |
dwg | dgn |
| S-37 | Weather Hood for Electrical Equipment Panel | |
dwg | dgn |
| S-38 | Typical Sanitary Sewer Service Backwater Valve Installation | |
dwg | dgn |
| S-39 | Pipe Alignment Guide (Spiders) | |
dwg | dgn |
| S-40 | Oil and Grease Trap Sizing | |
dwg | dgn |
| S-41 | Oil and Grease Trap Dimensions | |
dwg | dgn |
| S-42 | Typical Sewer Service Requiring Backwater Valve | |
dwg | dgn |
| S-43 | 8” & 10” Sanitary Sewer Easement Widths | |
dwg | dgn |
| S-44 | Standard Odor Control Building Front Elevation | |
dwg | dgn |
Contacts:
Cesar Sanchez
Public Utilities Department
Soil Erosion
Complete Soil Erosion Standard Detail Drawings:
Individual Soil Erosion Standard Detail Drawings:
| Detail | Description | Format | ||
| 40.02 | Standard Temporary (Sediment/Silt) Fence | |
dwg | dgn |
| 40.03 | Standard Temporary (Sediment/Silt)/ Tree Protection Fence | |
dwg | dgn |
| 40.04 | Standard Tree Protection Detail | |
dwg | dgn |
| 40.11 | Temporary Sediment Trap Outlet Detail | |
dwg | dgn |
| 40.12 | Temporary Sediment Trap | |
dwg | dgn |
| 40.13 | Rock Pipe Inlet Protection | |
dwg | dgn |
| 40.14 | Excavated Drop Inlet Protection | |
dwg | dgn |
| 40.15 | Check Dam | |
dwg | dgn |
| 40.21 | Construction Entrance | |
dwg | dgn |
| 40.22 | Residential Construction Entrance | |
dwg | dgn |
| 40.23 | Diversion Ditch | |
dwg | dgn |
| 40.24 | RIP RAP Lined Channels | |
dwg | dgn |
| 40.25 | Temporary Stream Crossing | |
dwg | dgn |
| 40.32 | Block and Gravel Drop Inlet Protection | |
dwg | dgn |
| 40.33 | Standard Catch Basin Yard Inlet Protection | |
dwg | dgn |
| 40.34 | Temporary Silt Ditch | |
dwg | dgn |
| 40.35 | Skimmer Sediment Basin | |
dwg | dgn |
| 40.36 | Sediment Basin | |
dwg | dgn |
| 40.37 | Temporary Riser | |
dwg | dgn |
| 40.38 | Skimmer | |
dwg | dgn |
| 40.39 | Standard Silt Fence Outlet | |
dwg | dgn |
| 40.40 | Block & Gravel Curb Inlet Sediment Filter | |
dwg | dgn |
| 40.41 | Concrete Washout | |
dwg | dgn |
Contact:
Ben Brown
Public Works Department
Street
Complete Street Standard Detail Drawings:
Individual Street Standard Detail Drawings:
| Detail | Description | Format | ||
| 20.01.1 | Driveway and Sidewalk (Sheet 1 of 2) | |
dwg | dgn |
| 20.01.2 | Driveway and Sidewalk (Sheet 2 of 2) | |
dwg | dgn |
| 20.02 | Driveway for Valley/Rolled Type Curb | |
dwg | dgn |
| 20.03 | Residential Driveway Installation on Non-Curb & Gutter Street | |
dwg | dgn |
| 20.04 | Driveway Grades | |
dwg | dgn |
| 20.11.1 | Sidewalk Access Ramps (Sheet 1 of 4) | |
dwg | dgn |
| 20.11.2 | Sidewalk Access Ramps (Sheet 2 of 5) | |
dwg | dgn |
| 20.11.3 | Sidewalk Access Ramps (Sheet 3 of 5) | |
dwg | dgn |
| 20.11.4 | Sidewalk Access Ramps (Sheet 4 of 5) | |
dwg | dgn |
| 20.11.5 | Sidewalk Access Ramps (Sheet 5 of 5) | |
dwg | dgn |
| 20.12 | Concrete/Brick Paver Sidewalk | |
dwg | dgn |
| 20.13 | Multi-Purpose Path | |
dwg | dgn |
| 20.21.1 | Curb & Gutters (Sheet 1 of 2) | |
dwg | dgn |
| 20.21.2 | Curb & Gutters (Sheet 2 of 2) | |
dwg | dgn |
| 20.31 | Residential Street | |
dwg | dgn |
| 20.32 | Residential Cul-De-Sac | |
dwg | dgn |
| 20.33.1 | 26' Stringline Reference (Sheet 1 of 4) | |
dwg | dgn |
| 20.33.2 | 31' Stringline Reference (Sheet 2 of 4) | |
dwg | dgn |
| 20.33.3 | 36' Stringline Reference (Sheet 3 of 4) | |
dwg | dgn |
| 20.33.4 | 41' Stringline Reference (Sheet 4 of 4) | |
dwg | dgn |
| 20.41 | Asphalt Pavement Patch | |
dwg | dgn |
Contacts:
Paul Kallam
Public Works Department
Trees
Complete Tree Standard Detail Drawings:
Individual Tree Standard Detail Drawings:
| Detail | Description | Format | ||
| 40.03 | Standard Temporary (Sediment/Silt)/Tree Protection Fence | |
dwg | dgn |
| 40.04 | Standard Tree Protection Detail | |
dwg | dgn |
| Deciduous Tree Planting Detail | |
dwg | dgn | |
| Tree Grate In Sidewalk Within ROW Detail | |
dwg | dgn | |
| Tree Protection Fence Detail | |
dwg | dgn | |
| Tree Planting In Sidewalk Within ROW Detail | |
dwg | dgn | |
Contact:
Forestry Specialist
Water
Complete Water Standard Detail Drawings:
Individual Water Standard Detail Drawings:
| Detail | Description | Format | ||
| W-1 | Standard Concrete Payment Patch | |
dwg | dgn |
| W-2 | Standard Asphalt Pavement Patch | |
dwg | dgn |
| W-3 | Trench Bottom Dimensions & Backfilling Requirements for Ductile Iron Pipe | |
dwg | dgn |
| W-4 | Standard Fire Hydrant Installation | |
dwg | dgn |
| W-5 | Standard Fire Hydrant with 5" Storz Pumper Nozzle | |
dwg | dgn |
| W-6 | Hydrant Operating Nut and 21/2" Outlet Threads | |
dwg | dgn |
| W-7 | Thrust Blocking Design Data for Water Mains | |
dwg | dgn |
| W-8 | Standard Thrust Block Installation for Valves and Dead End Mains | |
dwg | dgn |
| W-9 | Standard Thrust Blocking Views | |
dwg | dgn |
| W-10 | Thrust Blocking Design Quantity Table | |
dwg | dgn |
| W-11 | Thrust Blocking Design Quantity Table | |
dwg | dgn |
| W-12 | Standard Vertical Bend | |
dwg | dgn |
| W-13 | Standard Main & Valve Markers for Potable & Reuse Water Easements | |
dwg | dgn |
| W-14 | Standard Tapping Sleeve & Valve Assembly (4"-24") | |
dwg | dgn |
| W-15 | Restrained Tee and Valve Installation on Dead Lines (4"-24") | |
dwg | dgn |
| W-16 | Butterfly Valve Manhole (16" & Larger Mains) | |
dwg | dgn |
| W-17 | Valve Box Installation and Extension | |
dwg | dgn |
| W-18 | (51/4" Valve Box Drop Lid with 4" Skirt | |
dwg | dgn |
| W-19 | Standard Water Air Release Valve | |
dwg | dgn |
| W-20 | Standard Manhole Cover | |
dwg | dgn |
| W-21 | Temporary Water Main Blow Off Assembly | |
dwg | dgn |
| W-22 | Permanent Water Main Blow Off Assembly | |
dwg | dgn |
| W-23 | Standard ¾" & 1" Water Service Installation | |
dwg | dgn |
| W-24 | Single Family, Residential, New Construction Back flow Prevention/Meter Assembly Installation | |
dwg | dgn |
| W-25 | Water Meter Box Detail | |
dwg | dgn |
| W-26 | Standard Gang Meter Assembly | |
dwg | dgn |
| W-27 | Gang Meter Addressing Single Story Building | |
dwg | dgn |
| W-28 | Gang Meter Addressing Multi-Story Building | |
dwg | dgn |
| W-29 | Typical 4"-8" Domestic Water Meter Bypass Installation | |
dwg | dgn |
| W-30 | Typical 6"-10" Fire Service & Domestic Service w/ Bypass | |
dwg | dgn |
| W-31 | Typical 11/2"- 2" Water Meter Box Installation | |
dwg | dgn |
| W-32 | Typical 4" Water Meter Vault | |
dwg | dgn |
| W-33 | Typical 6" thru 10" Water Meter Vault | |
dwg | dgn |
| W-34 | Fire, Domestic & Irrigation Options Schematic | |
dwg | dgn |
| W-35 | Irrigation Tap on New and Existing Services | |
dwg | dgn |
| W-36 | Reduced Pressure Backflow Preventer | |
dwg | dgn |
| W-37 | Typical Fire Main Double Detector Check Valve Assembly | |
dwg | dgn |
| W-38 | Standard Double Check Valve Assembly | |
dwg | dgn |
| W-39 | Below Ground DDCV & DCV | |
dwg | dgn |
| W-40 | Pipe Alignment Guides (Spiders) | |
dwg | dgn |
Contacts:
Cesar Sanchez
Public Utilities Department
Miscellaneous
Complete Miscellaneous Standard Detail Drawings:
Individual Miscellaneous Standard Detail Drawings:
| Detail | Description | Format | ||
| 50.01 | Curb Drain Detail | |
dwg | dgn |
| 50.02 | Catch Basin Conversion Detail | |
dwg | dgn |
Contact:
Paul Kallam
Public Works Department
Menu