Unified Development Ordinance, 4th supplement, September 2017

Part 10A: Unified Development Ordinance City of Raleigh, North Carolina 2 – 23 Effective Date: September 01, 2013 Supp. No. 4 Article 2.4. ​​Conservation Development Option | CHAPTER 2. ​RESIDENTIAL DISTRICTS Sec. 2.4.5. Apartment Sec. 2.4.5. Apartment R-6 R-10 A. Lot Dimensions A1 Area (min) 15,000 sf 15,000 sf A2 Width (min) 100' 100' B. Building/Structure Setbacks B1 From primary street (min) 10' 10' B2 From side street (min) 10' 10' B3 From side lot line (min) 0' or 6' 0' or 6' B4 From rear lot line (min) 20' 20' B4 From alley 4' or 20' min 4' or 20' min C. Parking Setbacks C1 From primary street (min) 10' 10' C2 From side street (min) 10' 10' C3 From side/rear lot line (min) 0' or 3' 0' or 3' C4 From rear lot line (min) 3' 3' C4 From alley (min) 4' 4' R-6 R-10 D. Build-to D1 Primary street build-to (min/max) 10'/55' 10'/55' D2 Building width in primary build-to (min) 70% 70% D3 Side street build-to (min/max) 10'/55' 10'/55' D4 Building width in side build-to (min) 35% 35% E. Height E1 Principal building (max) 45'/3 stories 45'/3 stories E2 Accessory structure (max) 25' 25' F. Ground Floor Elevation F1 Within build-to (min) 2' 2' F2 Outside of build-to (min) 0' 0' G. Pedestrian Access G1 Street-facing entrance required (min 1 per building) yes yes H. Allowed Building Elements Porch, stoop Balcony See Sec. 1.5.4.D “Building Setbacks” for specific building element requirements. A2 A1 B2 B3 B4 B1 C3 C2 C4 C1 Building Setbacks Parking Setbacks Primary Street Alley Side Street G1 D1 D4 D2 D3 E1 E2 F1 Primary Street Alley Side Street